Online Links:
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 24 records have no value for subname. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 1411 records have no value for jobnumber. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 17 records have no value for fieldno. |
| Range of values | |
|---|---|
| Minimum: | 17.688611 |
| Maximum: | 69.666111 |
| Range of values | |
|---|---|
| Minimum: | -166.3 |
| Maximum: | -64.568333 |
| Range of values | |
|---|---|
| Minimum: | 174119 |
| Maximum: | 693958 |
| Resolution: | 1 |
| Value | Definition |
|---|---|
| N | North |
| Range of values | |
|---|---|
| Minimum: | 643406 |
| Maximum: | 1661800 |
| Resolution: | 1 |
| Value | Definition |
|---|---|
| W | West |
| Value | Definition |
|---|---|
| D | soil sample |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 15209 records have no value for methcoll. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 19624 records have no value for smplsrc. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 25839 records have no value for smpldesc. |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2167 records have no value for s_fe_. |
| Range of values | |
|---|---|
| Minimum: | 0.1 |
| Maximum: | 50 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2413 records have no value for s_mg_. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 20 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2424 records have no value for s_ca_. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 50 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2393 records have no value for s_ti_. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 13 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2157 records have no value for s_mn. |
| Range of values | |
|---|---|
| Minimum: | 0.002 |
| Maximum: | 700000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2102 records have no value for s_ag. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 700 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 5303 records have no value for s_as. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 10000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 6074 records have no value for s_au. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 1000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2507 records have no value for s_b. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 2000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2299 records have no value for s_ba. |
| Range of values | |
|---|---|
| Minimum: | 0.015 |
| Maximum: | 100000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2312 records have no value for s_be. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 200 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 5325 records have no value for s_bi. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 1000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 5316 records have no value for s_cd. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 150 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2308 records have no value for s_co. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 1000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2242 records have no value for s_cr. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 10000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2122 records have no value for s_cu. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 200000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2399 records have no value for s_la. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 600000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2110 records have no value for s_mo. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 2000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 3102 records have no value for s_nb. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 2000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2232 records have no value for s_ni. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 5000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2110 records have no value for s_pb. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 20000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 5302 records have no value for s_sb. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 20000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2656 records have no value for s_sc. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 300 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2147 records have no value for s_sn. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 3000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2341 records have no value for s_sr. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 10000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2220 records have no value for s_v. |
| Range of values | |
|---|---|
| Minimum: | 0.003 |
| Maximum: | 50000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 5257 records have no value for s_w. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 10000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2328 records have no value for s_y. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 7000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 5257 records have no value for s_zn. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 10000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 2363 records have no value for s_zr. |
| Range of values | |
|---|---|
| Minimum: | 0.003 |
| Maximum: | 50000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 23595 records have no value for s_th. |
| Range of values | |
|---|---|
| Minimum: | 50 |
| Maximum: | 5000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 17000 records have no value for aa_au_p. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 1700 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 14985 records have no value for inst_hg. |
| Range of values | |
|---|---|
| Minimum: | 0.01 |
| Maximum: | 20000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 28974 records have no value for aa_as_p. |
| Range of values | |
|---|---|
| Minimum: | 0.8 |
| Maximum: | 1000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 20283 records have no value for aa_cd_p. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 200 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 27425 records have no value for aa_sb_p. |
| Range of values | |
|---|---|
| Minimum: | 0.5 |
| Maximum: | 1000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 15153 records have no value for aa_zn_p. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 18300 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 20255 records have no value for aa_cu_p. |
| Range of values | |
|---|---|
| Minimum: | 0.02 |
| Maximum: | 18000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 21087 records have no value for aa_pb_p. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 120000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 20374 records have no value for aa_ag_p. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 154.1 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 26896 records have no value for si_f. |
| Range of values | |
|---|---|
| Minimum: | 40 |
| Maximum: | 17885 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 30833 records have no value for u_inst. |
| Range of values | |
|---|---|
| Minimum: | 0.05 |
| Maximum: | 8.98 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 30944 records have no value for as_pt. |
| Range of values | |
|---|---|
| Minimum: | 0.004 |
| Maximum: | 0.1 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 30944 records have no value for as_pd. |
| Range of values | |
|---|---|
| Minimum: | 0.002 |
| Maximum: | 0.1 |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 29376 records have no value for ph. |
| Range of values | |
|---|---|
| Minimum: | 2.02 |
| Maximum: | 8 |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 30974 records have no value for ash_. |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 19288 records have no value for cm_as. |
| Range of values | |
|---|---|
| Minimum: | 0 |
| Maximum: | 300000 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 30392 records have no value for cm_mo. |
| Range of values | |
|---|---|
| Minimum: | 2 |
| Maximum: | 30 |
| Value | Definition |
|---|---|
| L | The element was detected by the technique but at a level below the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| G | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| N | The element was not detected at concentrations above the lower limit of determination for the method. The value of the lower limit of determination is given in the adjacent data field. |
| H | The element was measured at a concentration greater than the upper determination limit for the method. The upper limit of determination is given in the adjacent data field. |
| B | The element was requested for analysis by the sample submitter, but for some reason the laboratories did not analyze for this element. |
| (no value) | The element was measured at the value indicated. |
| Value | Definition |
|---|---|
| (no value) | Information not available for this record. 30310 records have no value for cm_w. |
| Range of values | |
|---|---|
| Minimum: | 10 |
| Maximum: | 120 |
These data may be useful for mineral resource evaluation and for defining geochemical baseline values and statistics.
Online Links:
Are there legal restrictions on access or use of the data?Access_Constraints: None
Use_Constraints: None
These data are released on the condition that neither the U.S. Geological Survey (USGS) nor the United States Government may be held liable for any damages resulting from authorized or unauthorized use. The USGS provides these data "as is" and makes no guarantee or warranty concerning the accuracy of information contained in the data. The USGS further makes no warranties, either expressed or implied as to any other matter, whatsoever, including, without limitation, the condition of the product, or its fitness for any particular purpose. The burden for determining fitness for use lies entirely with the user.
| Data format: | Geochemical sample locations and analyses in format shapefile (version 1.0) Size: 1.6 |
|---|---|
| Network links: |
https://mrdata.usgs.gov/rass/soil/rasssoil.zip |